IsoTek EVO3 Mosaic Genesis Power Conditioner | Audio T
Your search results will appear here
IsoTek EVO3 Mosaic Genesis Power Conditioner and Generator

IsoTek EVO3 Mosaic Genesis Power Conditioner and Generator

Audio T Verdict

The IsoTek EVO3 Mosaic Genesis provides two different forms of power treatment within one substantial five-outlet component.

Three outlets create a newly generated, voltage-stabilised mains waveform for source components and preamplifiers. Two separate high-current outlets use IsoTek’s low-impedance Direct-Coupled design for power amplifiers, active loudspeakers and powered subwoofers.

This avoids the compromise of asking one filtering circuit to serve both delicate front-end electronics and components with much greater current demands.

The three regenerated outlets deliver 150W continuously between them, so their combined load must be checked carefully. The two high-current outlets provide up to 2,300W combined on the current UK specification.

With five independent outlets, voltage stabilisation, extensive noise reduction and progressive protection, the Mosaic Genesis is intended as a complete power-management solution for a carefully selected high-end audio or home cinema system.

IsoTek EVO3 Mosaic Genesis Power Conditioner and Generator

The EVO3 Mosaic Genesis combines technology from IsoTek’s Genesis mains regenerators and Titan high-current conditioners within one half-width chassis.

Source components and preamplifiers can receive a newly generated low-distortion mains supply, while power-hungry components use a separate Direct-Coupled conditioning network designed to maintain low impedance and current delivery.

This hybrid approach allows one unit to support a complete system without connecting a large power amplifier to the same regenerated output stage used by a streamer, DAC or phono stage.

Current Official UK Rating

IsoTek’s current specification lists the two high-current outlets at 2,300W combined and the mains input as 10A through an IEC C20 inlet.

Older IsoTek literature quote higher figures. Use the current ratings when planning the connected system.

Two Power-Cleaning Systems in One Chassis

Three Regenerated Outlets

  • Outlets 1 to 3
  • 150W continuous combined output
  • Newly generated mains sine wave
  • 0.03% published total harmonic distortion
  • 230V output stabilised within ±1%
  • For suitable source and control components

Two High-Current Outlets

  • Outlets 4 and 5
  • 2,300W combined UK rating
  • Passive Direct-Coupled conditioning
  • Very low-impedance power path
  • For amplifiers and powered speakers
  • Not part of the 150W regeneration stage

Newly Generated Power for Source Components

The first three outlets do more than pass the incoming electricity through a conventional filter.

A synchronous sine-wave generator creates a new waveform that is amplified and supplied to an output transformer. This regenerated supply is intended to provide a consistent waveform with very low distortion, rather than simply reducing high-frequency noise on the existing mains.

The regenerated waveform remains synchronised with the incoming supply frequency, helping avoid interactions between the incoming and generated electrical signals.

0.03% Total Harmonic Distortion

IsoTek specifies total harmonic distortion of 0.03% for the regenerated outlets.

Total harmonic distortion describes the unwanted harmonic content that changes the shape of the mains waveform away from an ideal sine wave.

The Mosaic Genesis rebuilds the waveform used by the first three outlets, reducing the influence of distortion already present on the incoming supply.

Voltage Stabilisation

The regenerated outlets also stabilise their output voltage at 230V within ±1% on the current UK model.

This can provide a more consistent supply where the incoming mains voltage varies during the day as demand on the local electricity network changes.

The voltage regulation applies to the three regenerated outlets rather than the two Direct-Coupled high-current outputs.

Suitable Regenerated-Outlet Components

  • Network streamers and music servers
  • CD and SACD players
  • DACs and digital processors
  • Turntable power supplies
  • Phono stages
  • Preamplifiers
  • Headphone amplifiers
  • Routers and network switches

The combined continuous consumption of everything connected to outlets 1 to 3 must not exceed 150W.

150W Is Shared Between Three Outlets

The regenerated section provides 150W continuously across all three outlets combined. It does not provide 150W from each socket.

For example, components consuming 30W, 40W and 50W would create a combined load of 120W and remain within the continuous rating.

Always use the manufacturer’s published power consumption rather than estimating from the product type or the output rating of an amplifier.

Do Not Connect Power Amplifiers to the Regenerated Outlets

Most integrated amplifiers, power amplifiers, active speakers and subwoofers can exceed the 150W combined limit.

These products should normally be connected to the dedicated high-current outlets.

Overload and Temperature Monitoring

The regeneration system monitors its operating conditions and can display an error if the 150W continuous limit is exceeded.

The unit also monitors internal temperature. Correct ventilation is therefore essential, particularly when the regeneration stage is supporting several components.

An error indication should not be ignored. Switch off the system, disconnect unsuitable loads and consult the operating guidance before restarting.

Direct-Coupled High-Current Conditioning

Outlets 4 and 5 use technology derived from IsoTek’s Titan conditioning products.

Rather than regenerating the mains, the Direct-Coupled network provides passive filtering through a low-resistance, low-impedance power path.

This arrangement is designed for equipment that can draw substantial current during operation, including large integrated amplifiers, power amplifiers, active speakers and powered subwoofers.

Why Amplifiers Need a Different Approach

A power amplifier may draw rapidly changing amounts of current as the music moves between quiet passages and demanding peaks.

A circuit intended for lower-powered source equipment may not provide the capacity required by these changes in demand.

The Mosaic Genesis therefore separates its high-current outlets from the 150W regeneration engine, allowing the amplifier section of a system to use an appropriately rated conditioning network.

Current UK High-Current Capacity

IsoTek’s current product specification lists a combined maximum of 2,300W for outlets 4 and 5 on UK, European, Australian and Swiss versions.

This capacity is shared between both high-current outlets and remains subject to the rating of the Mosaic Genesis, its input cable, wall socket and household electrical circuit.

Do not calculate the connected load by adding the amplifier’s channel-output figures. Use its published mains consumption or rear-panel electrical rating.

Suitable High-Current Components

  • Integrated amplifiers
  • Stereo power amplifiers
  • Mono power amplifiers
  • Home cinema receivers
  • Active loudspeakers
  • Powered subwoofers

Five Independent Outlets

The five outlets are independently connected rather than being linked together as one simple series of sockets.

This architecture is designed to reduce Differential Mode noise passing from one connected component into another through the power distributor.

Switch-mode power supplies, digital products and network equipment can all return electrical noise to the mains, so separating the outlet paths can be useful even when the incoming household supply is relatively clean.

Common Mode and Differential Mode Noise

Common Mode noise is interference appearing in relation to earth and can include radio-frequency energy from wireless networks, mobile communications and nearby electrical devices.

Differential Mode noise appears between live and neutral and can be produced by the power supplies inside connected equipment.

The Mosaic Genesis is designed to address both forms of contamination through its regenerated and Direct-Coupled sections.

Reducing Cross-Contamination

Every powered component can affect the electrical environment around the other products connected to it.

A network switch, television or digital source may introduce switching noise, while an amplifier can place a rapidly changing load on the supply.

The Mosaic Genesis uses independent outlet paths and dedicated treatment for different component types to reduce these interactions.

KERP Power Distribution

IsoTek describes its internal architecture as KERP, meaning Kirchhoff’s Equal Resistance Path.

The design aims to maintain equal resistance and consistent power delivery between the relevant outlet paths, rather than allowing one socket to receive a less direct connection through the unit.

This principle works alongside the independent filtering and regeneration networks.

Silver-Plated OCC Internal Wiring

The internal power path uses solid-core Ohno Continuous Cast copper with silver plating.

OCC processing is intended to produce long copper crystal structures with relatively few boundaries, while the silver-plated surface provides a highly conductive outer layer.

The internal wiring is selected to provide low resistance between the mains inlet, conditioning circuits and output sockets.

Virtual Air Dielectric Construction

A Fluorinated Ethylene Propylene helix is wound around the internal conductor before an outer FEP layer is applied.

This reduces the amount of solid insulation in direct contact with the conductor, creating what IsoTek calls a Virtual Dielectric of Air.

The construction is intended to combine electrical insulation with low capacitance and controlled internal geometry.

Progressive Surge and Spike Protection

The Mosaic Genesis includes a progressive protection network intended to respond to abnormal surges and voltage spikes.

This protection is designed to help safeguard the conditioner and suitably connected equipment, but no protection system can guarantee survival from every electrical event.

The unit should be disconnected during electrical storms where practical, and it must not be treated as protection against a direct lightning strike.

Protection Is Not a Substitute for Correct Installation

The Mosaic Genesis must be connected to a correctly wired and earthed mains supply.

Have the wall socket and household circuit checked by a qualified electrician if their condition or earthing is uncertain.

Front-Panel Display

The front display provides information about the incoming and regenerated mains supply.

Available readings include incoming voltage, mains frequency and distortion, together with regenerated output voltage, output distortion and connected power consumption.

This allows the user to see both the condition of the incoming supply and the operation of the regeneration system.

Black or Silver Finish

The substantial aluminium chassis is available in Black or Silver to complement different equipment finishes.

Its half-width footprint is relatively compact across the front, although the 470mm depth and required ventilation space must be considered carefully.

At 20kg, it requires a strong, stable shelf rather than lightweight furniture.

Placement and Ventilation

The Mosaic Genesis produces heat while regenerating the mains waveform and must have adequate airflow around its ventilation openings.

Allow ventilation beneath the unit, keep the upper vents clear and do not install it inside a sealed cabinet.

Keep it away from direct sunlight, radiators, amplifiers that run very hot and other sources of excessive temperature.

Do Not Block the Ventilation

IsoTek’s safety guidance warns that an internal temperature above 75°C can trigger an overheating error.

Do not stack another component directly on top of the Mosaic Genesis or place it on a soft surface that obstructs ventilation underneath.

Understanding the Error Display

  • E1: The regenerated load has exceeded the 150W continuous limit
  • E2: Internal temperature has exceeded the permitted level
  • E4: Incoming voltage is outside the regeneration correction range

If an error appears, switch off the connected equipment and Mosaic Genesis before investigating the cause.

Do not open the chassis. There are no user-serviceable components inside.

IEC C20 Mains Inlet

The current official specification lists a 10A-rated IEC C20 mains inlet.

A C20 inlet accepts an IEC C19 equipment connector, which is physically different from the smaller C13 connector found on many source components.

Use the correctly terminated cable supplied with the unit or a suitable approved replacement with matching electrical ratings.

EVO3 Premier Power Cable Included

The Mosaic Genesis is supplied with an IsoTek EVO3 Premier power cable for connection to the mains supply.

The cable should reach the wall socket without tension and must not be trapped, sharply bent or tightly coiled behind the equipment rack.

Alternative IsoTek cables may be considered as a later upgrade, provided their connection and electrical ratings are suitable.

Planning a Complete System

Before installation, list every component together with its connector type and published power consumption.

Place lower-powered sources and control products on regenerated outlets 1 to 3, while assigning amplifiers, active loudspeakers and subwoofers to outlets 4 and 5.

Where a system includes more than two high-current products, additional conditioning or a revised power layout may be required.

Example System Layout

Regenerated Outlets 1 to 3

  • Network streamer
  • DAC or CD player
  • Preamplifier or phono stage

High-Current Outlets 4 and 5

  • Stereo power amplifier
  • Powered subwoofer

This is only an example. The correct arrangement depends on the actual consumption and connector requirements of the equipment.

Installation Guide

  • Confirm that the supporting shelf can carry at least 20kg plus any safety margin
  • Allow airflow above, below and around the chassis
  • Check the power consumption of every component
  • Keep the combined regenerated load below 150W
  • Reserve outlets 4 and 5 for high-current equipment
  • Switch off all equipment before making connections
  • Connect the supplied power cable securely to the IEC C20 inlet
  • Connect source equipment to outlets 1 to 3
  • Connect amplifiers or powered speakers to outlets 4 and 5
  • Arrange cables without tension or sharp bends
  • Switch on the Mosaic Genesis before the connected components
  • Check the front-panel readings and connected load
  • Investigate any error code before continuing

What Might You Hear?

Reducing mains noise and providing a more consistent supply may allow a suitably revealing system to reproduce low-level information more clearly.

Possible improvements include cleaner bass definition, greater separation, a quieter perceived background and more stable stereo imaging.

The scale and character of any change will depend on the incoming mains, connected equipment, existing power products and the resolution of the complete system.

Power Conditioning or Regeneration?

Conventional power conditioning filters the incoming mains while allowing the original waveform to pass through the product.

Power regeneration creates a new waveform for the connected equipment, offering control over voltage and distortion as well as high-frequency noise.

The Mosaic Genesis uses both methods because regeneration is best suited to its lower-powered outlets, while Direct-Coupled conditioning provides the capacity required by larger amplifiers.

Mosaic Genesis or V5 Sigmas?

Choose Mosaic Genesis When

  • True mains regeneration is required for source equipment
  • Voltage stabilisation is important
  • Three front-end and two high-current outlets are sufficient
  • The connected regenerated load remains below 150W
  • A hybrid generator and conditioner is preferred

Choose V5 Sigmas When

  • Six conditioned outlets are required
  • Regeneration is not essential
  • A current V5 passive conditioner is preferred
  • Four medium-power and two high-current outlets suit the system
  • A more conventional full-width component is suitable

The IsoTek V5 Sigmas is a six-outlet passive power conditioner with dedicated medium-power and high-current sections.

Related IsoTek Products and Audio T Guides

Key Features

  • Hybrid mains generator and power conditioner
  • Five independent UK output sockets
  • Three regenerated source-component outlets
  • Two Direct-Coupled high-current outlets
  • 150W regenerated continuous output in total
  • 2,300W combined high-current UK rating
  • 0.03% published regenerated-output THD
  • 230V regenerated output stabilised within ±1%
  • Synchronous sine-wave generation
  • Designed to reduce Common Mode noise
  • Designed to reduce Differential Mode noise
  • Independent outlets reduce cross-contamination
  • KERP equal-resistance internal architecture
  • Solid-core OCC copper internal wiring
  • Silver-plated internal conductors
  • FEP Virtual Air Dielectric construction
  • Low-impedance high-current conditioning
  • Progressive surge and spike protection
  • Incoming and output mains display
  • Load and temperature monitoring
  • Overload and operating error indications
  • 10A IEC C20 mains inlet
  • EVO3 Premier power cable supplied
  • Black or Silver finish
  • 225mm half-width chassis
  • 20kg product weight

Frequently Asked Questions

Is the Mosaic Genesis a conditioner or a regenerator?

It is both. Three outlets receive regenerated mains, while two separate outlets use high-current Direct-Coupled conditioning.

How many outlets does it provide?

It provides five independent output sockets.

Which outlets are regenerated?

Outlets 1 to 3 provide the newly generated, voltage-stabilised mains supply.

How much regenerated power is available?

The three regenerated outlets share a continuous total of 150W.

Is the 150W rating available from each outlet?

No. It is the combined continuous limit for all three regenerated outlets.

What should be connected to the regenerated outlets?

Suitable products include streamers, DACs, CD players, phono stages, preamplifiers and other relatively low-powered components.

Which outlets are intended for amplifiers?

Outlets 4 and 5 use the Direct-Coupled high-current conditioning network.

What is the current UK high-current rating?

IsoTek’s current specification lists 2,300W combined across the two high-current outlets.

Does the Mosaic Genesis stabilise the voltage?

Yes. The regenerated outlets provide a nominal 230V output stabilised within ±1%.

What is the regenerated output distortion?

IsoTek currently publishes total harmonic distortion of 0.03%.

Can a power amplifier be connected to a regenerated outlet?

It is generally unsuitable because the regenerated section has a 150W combined limit. Use a high-current outlet unless the amplifier manufacturer and Audio T confirm otherwise.

What does the front display show?

It can display information including incoming and output voltage, mains distortion, frequency and connected regenerated power consumption.

What do the error codes mean?

E1 indicates a regenerated-output overload, E2 indicates overheating and E4 indicates incoming voltage outside the correction range.

Does it require ventilation?

Yes. Airflow beneath and around the unit is essential, and its ventilation openings must remain clear.

Is a power cable supplied?

Yes. An IsoTek EVO3 Premier power cable is supplied.

Why Buy From Audio T?

  • Specialist IsoTek demonstrations
  • Complete system power-consumption checks
  • Regenerated and high-current outlet planning
  • Amplifier and source-component matching
  • Power-cable and connector guidance
  • Comparison with V5 Aquarius, Sigmas and Titan
  • Equipment-rack and ventilation advice
  • Home demonstrations where available
  • Ongoing installation and system support

Contact your local Audio T store to discuss the power consumption and correct outlet arrangement for your complete system.

Core Specification

  • Product type: Hybrid mains regenerator and power conditioner
  • Model: IsoTek EVO3 Mosaic Genesis
  • Number of outlets: Five
  • Outlet configuration: Three regenerated and two high-current conditioned
  • Available finishes: Black or Silver
  • UK outlet type: UK mains sockets

Regenerated Outlets 1 to 3

  • Technology: Synchronous mains sine-wave generation
  • Continuous output: 150W combined across all three outlets
  • Published total harmonic distortion: 0.03%
  • Nominal UK output voltage: 230V
  • Voltage stabilisation: ±1%
  • Recommended applications: Source components, preamplifiers and other lower-powered equipment
  • Overload indication: E1 error when the continuous load exceeds 150W

High-Current Outlets 4 and 5

  • Technology: IsoTek Direct-Coupled passive conditioning
  • Current UK output rating: 2,300W combined
  • Regenerated output: No
  • Design priority: Low impedance and high-current delivery
  • Recommended applications: Integrated amplifiers, power amplifiers, active speakers and powered subwoofers
  • Load calculation: Use the equipment’s published mains consumption

Noise Reduction and Outlet Design

  • Common Mode noise treatment: Yes
  • Differential Mode noise treatment: Yes
  • Independent outlet paths: Yes
  • Cross-contamination control: Designed to reduce noise passing between connected products
  • Internal architecture: KERP equal-resistance power path
  • High-current circuit: Derived from IsoTek Titan Direct-Coupled technology

Internal Construction

  • Internal conductor material: Ohno Continuous Cast copper
  • Conductor format: Solid core
  • Conductor finish: Silver plated
  • Dielectric: Fluorinated Ethylene Propylene
  • IsoTek dielectric design: Virtual Dielectric of Air
  • Chassis: Substantial aluminium enclosure

Protection and Monitoring

  • Surge and spike protection: Progressive protection network
  • Regenerated-load monitoring: Yes
  • Temperature monitoring: Yes
  • E1 indication: Regenerated load above 150W
  • E2 indication: Internal temperature above 75°C
  • E4 indication: Incoming voltage outside the correction range
  • 50Hz correction range: 207V to 253V

Front-Panel Information

  • Incoming voltage display: Yes
  • Incoming THD display: Yes
  • Mains-frequency display: Yes
  • Output-voltage display: Yes
  • Output-THD display: Yes
  • Regenerated power-consumption display: Yes

Mains Input

  • Current official inlet rating: 10A
  • Mains inlet: IEC C20
  • Required cable connector: IEC C19
  • UK mains voltage: 230V model
  • Mains frequency: 50Hz model
  • Supplied power cable: IsoTek EVO3 Premier

Dimensions and Weight

  • Width: 225mm
  • Height: 225mm
  • Depth: 470mm
  • Weight: 20kg
  • Format: Half-width chassis
  • Supporting surface: Strong, rigid and level

Installation Requirements

  • Ventilation beneath unit: Required
  • Top ventilation: Must remain unobstructed
  • Direct sunlight: Avoid
  • Sealed cabinet installation: Not recommended
  • Protective earth: Correctly earthed mains supply required
  • User-serviceable components: None
  • Regenerated load check: Required before use